2-WIRE RS-485 TESTING
USING LOOPBACK OR WITHOUT LOOPBACK
PAGE 5 OF 9
CONNECTIONS - Models Without Echo Jumper
USING COMTEST TO CHECK OPERATION - models with echo jumper
1. Make the Test Connections for Loopback and the required setting to Enable RX or Echo.
2. Start ComTest from your Programs menu under B&B Electronics.
3. Select the Com port number you want to check. ComTest will only show Windows based
Com ports that are not in use. If another program is using the port, it will not be available.
Please close down any other programs that may be accessing the port. If another program is
using the same IRQ number that port is using, you will not be able to use both ports at once
unless both devices are PCI or USB based.
4. Accept the default baud rate, data bits, parity, stop bits.