RS-422/485 Application Note 27
Copyright B&B Electronics -- Revised October 1997
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350
PH (815) 433-5100 -- FAX (815) 434-7094
Vcc
Port
Device
Data Lines
Local Chassis Ground Connection
Ground line
Figure 4.5 RS-485 Device with Signal Ground
Connected to Chassis Ground
Transient protection using Isolation
Isolation Theory
The most universal approach to protecting against transients is to
galvanically isolate the data port from the host device circuitry. This method
separates the signal reference from any fixed ground. Optical isolators,
transformers and fiber optics are all methods commonly used in many types of
data networks to isolate I/O circuitry from its host device. In RS-422 and RS-
485 applications, optical isolators are most common. An optical isolator is an
integrated circuit that converts the electrical signal to light and back, eliminating
electrical continuity. With an isolated port, the entire isolated circuitry floats to
the level of the transient without disrupting data communications. As long as the
floating level of the circuitry does not exceed the breakdown rating of the
isolators (typically 1000 - 2500 volts) the port will not be damaged. This type of
protection does not attempt to absorb or shunt excess energy so it is not sensitive
to the length of the transient. Even continuous potential differences will not
harm isolated devices. It is important to note that isolators work on common
mode transients, they cannot protect against large voltage differences between
conductors of a data cable such as those caused by short circuits between data
and power circuits.