AN1 – upper limit (with sign)
bits 7-3:
AN1 – metering circuit switch time
0 → 1/64 sec
1 → 2/64 sec
...
30 → 31/64 sec
bits 2-0:
AN1 – samples number for average
0 → 1 sample
1 → 2 samples
2 → 4 samples
4 → 8 samples
5 → 16 samples
AN2 – samples period [sec]
AN2 – multiplicative constant (with sign)
AN2 – additive constant (with sign)
AN2 – hysteresis value (with sign)
AN2 – lower limit (with sign)
AN2 – upper limit (with sign)
bits 7-3:
AN2 – metering circuit switch time
0 → 1/64 sec
1 → 2/64 sec
...
30 → 31/64 sec
bits 2-0:
AN2 – samples number for average
0 → 1 sample
1 → 2 samples
2 → 4 samples
4 → 8 samples
5 → 16 samples
CNT1 – multiplicative constant
CNT1 – time of limit overrun [sec]
CNT1 – time for metering reset [sec]