Required Serial Settings
Use the following serial port settings to
allow the communication device to
interface with the Opticom™ Infrared
System phase selector:
Model 752 / 754
Infrared
Phase Selectors
Model 1000
GPS
Phase Selectors
1
Baud rate
9600
115,200
Parity
None
None
Data bits
8
8
Flow control
None
None
Cabling
For devices with DB-9 connectors, use
these cables to connect between the
device’s serial port and the phase
selector:
Model 752 / 754
Infrared Phase
Selectors
Model 1000 GPS
Phase Selectors
2
Cable
DB-9 to 6-pin mini-
DIN serial
communications
cable (GTT model
C50005)
DB-9 to DB-9
serial
communications
cable
Some devices require different cables
and/or additional adapters; see the
“Cabling” section for the device.
All serial device servers included in this
document use a standard Ethernet cable
for connecting the Ethernet port to your
network.
1,2 This information on Opticom GPS phase
selectors is provided for reference only. These
devices were not included in the GTT lab
testing as they were not yet supported by
Opticom™ Central Management Software.